Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 11(9)2021 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-34573972

RESUMO

The tremendous advances in multiplex immunoassays (MIAs) are leading to novel in vitro diagnostics (IVD) and point-of-care testing (POCT) [...].

2.
Diagnostics (Basel) ; 10(4)2020 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-32260471

RESUMO

There have been tremendous advances in in vitro diagnostic (IVD) assays for coronavirus disease 2019 (COVID-19) caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The main IVD assays used for COVID-19 employ real-time reverse transcriptase polymerase chain reaction (RT-PCR) that takes a few hours. But the assay duration has been shortened to 45 min by Cepheid. Of interest is the point-of-care (POC) molecular assay by Abbott that decreased the assay duration to just 5 min. Most molecular tests have been approved by the United States Food and Drug Administration (FDA) under emergency use authorization (EUA) and are Conformité Européenne (CE) marked. A wide range of serology immunoassays (IAs) have also been developed that complement the molecular assays for the diagnosis of COVID-19. The most prominent IAs are automated chemiluminescent IA (CLIA), manual ELISA, and rapid lateral flow IA (LFIA), which detect the immunoglobulin M (IgM) and immunoglobulin G (IgG) produced in persons in response to SARS-CoV-2 infection. The ongoing research efforts and advances in complementary technologies will pave the way to new POC IVD assays in the coming months. However, the performance of IVD assays needs to be critically evaluated before they are employed for the clinical diagnosis of COVID-19.

3.
Carbon N Y ; 50(4): 1625-1634, 2019 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-31105316

RESUMO

Carbon nanotubes (CNTs) have emerged as promising drug delivery systems particularly for cancer therapy, due to their abilities to overcome some of the challenges faced by cancer treatment, namely non-specificity, poor permeability into tumour tissues, and poor stability of anticancer drugs. Encapsulation of anticancer agents inside CNTs provides protection from external deactivating agents. However, the open ends of the CNTs leave the encapsulated drugs exposed to the environment and eventually their uncontrolled release before reaching the desired target. In this study, we report the successful encapsulation of cisplatin, a FDA-approved chemotherapeutic drug, into multi-walled carbon nanotubes and the capping at the ends with functionalised gold nanoparticles to achieve a "carbon nanotube bottle" structure. In this proof-of-concept study, these caps did not prevent the encapsulation of drug in the inner space of CNTs; on the contrary, we achieved higher drug loading inside the nanotubes in comparison with data reported in literature. In addition, we demonstrated that encapsulated cisplatin could be delivered in living cells under physiological conditions to exert its pharmacological action.

4.
Biosensors (Basel) ; 7(4)2017 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-29258285

RESUMO

Recent years have witnessed tremendous advances in point-of-care diagnostics (POCD), which are a result of continuous developments in biosensors, microfluidic, bioanalytical platforms, assay formats, lab-on-a-chip technologies, and complementary technologies. This special issue targets the critical advances in POCD and provides guided insights and directions for future research.


Assuntos
Técnicas Biossensoriais , Técnicas de Diagnóstico Molecular , Sistemas Automatizados de Assistência Junto ao Leito , Biotecnologia , Humanos
5.
Methods Mol Biol ; 1571: 343-356, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28281266

RESUMO

A smartphone-based colorimetric reader (SBCR), comprising a Samsung Galaxy SIII mini, a gadget (iPAD mini, iPAD4, or iPhone 5s) and a custom-made dark hood and base holder assembly, is used for human C-reactive protein (CRP) immunoassay. A 96-well microtiter plate (MTP) is positioned on the gadget's screensaver to provide white light-based bottom illumination only in the specific regions corresponding to the well's bottom. The images captured by the smartphone's back camera are analyzed by a novel image processing algorithm. Based on one-step kinetics-based human C-reactive protein immunoassay (IA), SBCR is evaluated and compared with a commercial MTP reader (MTPR). For analysis of CRP spiked in diluted human whole blood and plasma as well as CRP in clinical plasma samples, SBCR exhibits the same precision, dynamic range, detection limit, and sensitivity as MTPR for the developed IA (DIA). Considering its compactness, low cost, advanced features and a remarkable computing power, SBCR is an ideal point-of-care (POC) colorimetric detection device for the next-generation of cost-effective POC testing (POCT).


Assuntos
Proteína C-Reativa/análise , Colorimetria/instrumentação , Colorimetria/métodos , Imunoensaio/instrumentação , Imunoensaio/métodos , Smartphone , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Proteína C-Reativa/urina , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Estatística como Assunto/métodos
6.
Trends Biotechnol ; 35(5): 407-421, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28094081

RESUMO

Human fetuin A (HFA) plays a prominent pathophysiological role in numerous diseases and pathophysiological conditions with considerable biomedical significance; one example is the formation of calciprotein particles in osteoporosis and impaired calcium metabolisms. With impressive advances in in vitro diagnostic assays during the last decade, ELISAs have become a workhorse in routine clinical diagnostics. Recent diagnostic formats involve high-sensitivity immunoassay procedures, surface plasmon resonance, rapid immunoassay chemistries, signal enhancement, and smartphone detection. The current trend is toward fully integrated lab-on-chip platforms with smartphone readouts, enabling health-care practitioners and even patients to monitor pathological changes in biomarker levels. This review provides a critical analysis of advances made in HFA assays along with the challenges and future prospects.


Assuntos
Técnicas Biossensoriais/tendências , Análise Química do Sangue/tendências , Condutometria/tendências , Imunoensaio/tendências , Aplicativos Móveis/tendências , Testes Imediatos/tendências , alfa-2-Glicoproteína-HS/análise , Biomarcadores/sangue , Equipamentos Descartáveis/tendências , Humanos , Smartphone/tendências , Ressonância de Plasmônio de Superfície/tendências , alfa-2-Glicoproteína-HS/imunologia
7.
Biosens Bioelectron ; 89(Pt 1): 293-304, 2017 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-26620098

RESUMO

Two-dimensional (2D) graphene, sp2-hybridized carbon, and its two major derivatives, graphene oxide (GO) and reduced graphene oxide (rGO) have played an important role in immunoassays (IAs) and immunosensing (IMS) platforms for the detection of carcinoembryonic antigen (CEA), an implicated tumor biomarker found in several types of cancer. The graphene family with high surface area is functionalized to form stable nanocomposites with gold nanoparticles (AuNPs) and electron mediators. The capture anti-CEA antibody (Ab) with high density can be anchored on AuNPs of such composites to provide remarkable detection sensitivity, significantly below the level found in normal subjects and cancer patients. Electrochemical and fluorescence/chemiluminescence-quenching properties of graphene-based nanocomposites are exploited in various detection schemes. Future endeavors are envisioned for the development of an array platform with high-throughput for CEA together with other tumor biomarkers and C-reactive protein, a universal biomarker for infection and inflammation. The ongoing efforts dedicated to the replacement of a lab-based detector by a cellphone with smart applications will further enable cost-effective and frequent monitoring of CEA in order to establish its clinical relevance and provide tools for real-time monitoring of patients during chemotherapy.


Assuntos
Técnicas Biossensoriais/métodos , Antígeno Carcinoembrionário/sangue , Grafite/química , Imunoensaio/métodos , Nanocompostos/química , Animais , Anticorpos Imobilizados/química , Aptâmeros de Nucleotídeos/química , Biomarcadores Tumorais/análise , Biomarcadores Tumorais/sangue , Técnicas Biossensoriais/instrumentação , Antígeno Carcinoembrionário/análise , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Ouro/química , Humanos , Imunoensaio/instrumentação , Medições Luminescentes/instrumentação , Medições Luminescentes/métodos , Nanopartículas Metálicas/química , Nanopartículas Metálicas/ultraestrutura , Modelos Moleculares , Nanocompostos/ultraestrutura , Neoplasias/sangue , Oxirredução , Óxidos/química
8.
Biosens Bioelectron ; 93: 198-204, 2017 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-27614682

RESUMO

A sensitive and rapid sandwich immunoassay (IA) was developed for human lipocalin-2 (LCN2) by functionalizing a KOH-treated polystyrene microtiter plate with multiwalled carbon nanotubes (MWCNTs) dispersed in 3-aminoproyltriethoxysilane (APTES). The significantly increased surface area due to the presence of MWCNTs led to a high immobilization density of 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) activated anti-LCN2 capture antibodies (Ab). The anti-LCN2 Ab-bound MTPs were stable for 6 weeks when stored in 0.1M PBS, pH 7.4 at 4°C. The IA detects LCN2 from 0.6 to 5120pgmL-1 with a limit of detection (LOD) and limit of quantification (LOQ) of 0.9pgmL-1 and 6pgmL-1, respectively. The assay offered a ~50-fold lower LOD and ~3-fold faster IA, compared to a commercial sandwich enzyme-linked immunosorbent assay kit.


Assuntos
Técnicas Biossensoriais , Imunoensaio , Lipocalina-2/isolamento & purificação , Nanotubos de Carbono/química , Humanos , Lipocalina-2/química , Propilaminas/química , Silanos/química
9.
Anal Chim Acta ; 938: 129-36, 2016 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-27619095

RESUMO

A surface plasmon resonance (SPR) biosensor has been developed for rapid immunoassay of procalcitonin (PCT) with high detection sensitivity and reproducibility. The 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide hydrochloride (EDC)-activated protein A (PrA), diluted in 1% (v/v) 3-aminopropyltriethoxysilane (APTES) was dispensed on a KOH-treated Au-coated SPR chip, resulting in the covalent binding of PrA in 30 min. This "single-step" PrA immobilization strategy led to the oriented binding of the anti-PCT antibody (Ab) on a PrA-functionalized gold (Au) chip. The leach-proof immobilization procedure is five-fold faster than conventional counterparts, enabling high detection specificity and reproducibility. The IA detects 4-324 ng mL(-1) of PCT with a limit of detection (LOD) and a limit of quantification (LOQ) of 4.2 ng mL(-1) and 9.2 ng mL(-1), respectively. It was capable of detecting PCT in real sample matrices and patient samples with high precision. The Ab-bound SPR chips were stable for more than five weeks.


Assuntos
Calcitonina/análise , Imunoensaio/métodos , Ressonância de Plasmônio de Superfície/métodos , Humanos , Limite de Detecção
10.
Anal Chim Acta ; 929: 1-22, 2016 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-27251944

RESUMO

The last decade has witnessed tremendous advances in employing microfluidic solutions enabling Continuous Processing and Monitoring of Biological Samples (CPMBS), which is an essential requirement for the control of bio-processes. The microfluidic systems are superior to the traditional inline sensors due to their ability to implement complex analytical procedures, such as multi-step sample preparation, and enabling the online measurement of parameters. This manuscript provides a backgound review of microfluidic approaches employing laminar flow, hydrodynamic separation, acoustophoresis, electrophoresis, dielectrophoresis, magnetophoresis and segmented flow for the continuous processing and monitoring of biological samples. The principles, advantages and limitations of each microfluidic approach are described along with its potential applications. The challenges in the field and the future directions are also provided.


Assuntos
Técnicas de Química Analítica/métodos , Técnicas Analíticas Microfluídicas/métodos , Animais , Técnicas de Química Analítica/instrumentação , Desenho de Equipamento , Humanos , Hidrodinâmica , Técnicas Analíticas Microfluídicas/instrumentação
11.
Biotechnol Adv ; 34(3): 272-90, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26717866

RESUMO

This review presents advances in assays for human C-reactive protein (CRP), the most important biomarker of infection and inflammation for a plethora of diseases and pathophysiological conditions. Routine assays in clinical settings are based on analyzers, enzyme-linked immunosorbent assays and lateral flow assays. However, assays encompassing novel sensing schemes, improved chemistry, signal enhancement, lab-on-a-chip, microfluidics and smartphone detection, have emerged in recent years. The incorporation of immune-transducing chips or sensing interfaces with nanomaterials enables multiplexing analysis of CRP with co-existing biomarkers. However, there are still considerable challenges in the development of rapid diagnostics for both pentameric and monomeric CRP forms.


Assuntos
Proteína C-Reativa/análise , Técnicas de Química Analítica , Proteína C-Reativa/fisiologia , Humanos
12.
Trends Biotechnol ; 33(11): 692-705, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26463722

RESUMO

Considerable advances in point-of-care testing (POCT) devices stem from innovations in cellphone (CP)-based technologies, paper-based assays (PBAs), lab-on-a-chip (LOC) platforms, novel assay formats, and strategies for long-term reagent storage. Various commercial CP platforms have emerged to provide cost-effective mobile health care and personalized medicine. Such assay formats, as well as low-cost PBAs and LOC-based assays, are paving the way to robust, automated, simplified, and cost-effective POCT. Strategies have also been devised to stabilize reagent storage and usage at ambient temperature. Nevertheless, successful commercialization and widespread implementation of such clinically viable technologies remain subject to several challenges and pending issues.


Assuntos
Testes Diagnósticos de Rotina/métodos , Testes Imediatos , Humanos
13.
Anal Chim Acta ; 883: 74-80, 2015 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-26088779

RESUMO

A rapid sandwich immunoassay (IA) with enhanced signal response for human fetuin A (HFA) was developed by modifying the surface of a KOH-treated polystyrene microtiter plate (MTP) with agarose and 3-aminopropyltriethoxysilane (APTES). The agarose-APTES complex binds covalently to the hydroxyl moiety of the MTP plate to serve as a binding platform for bioconjugation of EDC-activated anti-HFA antibody (Ab) via carbodiimide coupling. The one-step kinetics-based sandwich enzyme-linked immunosorbent assay (ELISA) enabled the detection of HFA in 30 min with a limit of detection (LOD) and a linear range of 0.02 ng mL(-1) and 1-243 ng mL(-1), respectively. It detected HFA spiked in diluted human whole blood and serum, and HFA in ethylenediaminetetraacetic acid (EDTA)-plasma of patients with high precision similar to that of conventional ELISA. The anti-HFA Ab-bound agarose-functionalized MTPs retained their functional activity after 6 weeks of storage in 0.1 M PBS, pH 7.4 at 4 °C.


Assuntos
Anticorpos Imobilizados/química , Imunoensaio/métodos , Propilaminas/química , Sefarose/análogos & derivados , Silanos/química , alfa-2-Glicoproteína-HS/análise , Humanos , Imunoensaio/economia , Limite de Detecção
14.
Biosens Bioelectron ; 67: 248-55, 2015 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-25168283

RESUMO

A smartphone-based colorimetric reader (SBCR) was developed using a Samsung Galaxy SIII mini, a gadget (iPAD mini, iPAD4 or iPhone 5s), integrated with a custom-made dark hood and base holder assembly. The smartphone equipped with a back camera (5 megapixels resolution) was used for colorimetric imaging via the hood and base-holder assembly. A 96- or 24-well microtiter plate (MTP) was positioned on the gadget's screensaver that provides white light-based bottom illumination only in the specific regions corresponding to the bottom of MTP's wells. The pixel intensity of the captured images was determined by an image processing algorithm. The developed SBCR was evaluated and compared with a commercial MTP reader (MTPR) for three model assays: our recently developed human C-reactive protein sandwich enzyme-linked immunosorbent assay (ELISA), horseradish peroxidase direct ELISA, and bicinchoninic acid protein estimation assay. SBCR had the same precision, dynamic range, detection limit and sensitivity as MTPR for all three assays. With advanced microfabrication and data processing, SBCR will become more compact, lighter, inexpensive and enriched with more features. Therefore, SBCR with a remarkable computing power could be an ideal point-of-care (POC) colorimetric detection device for the next-generation of cost-effective POC diagnostics, immunoassays and diversified bioanalytical applications.


Assuntos
Técnicas Biossensoriais/instrumentação , Colorimetria/instrumentação , Ensaio de Imunoadsorção Enzimática/instrumentação , Iluminação/instrumentação , Aplicativos Móveis , Smartphone , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Biosens Bioelectron ; 67: 73-8, 2015 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-25022575

RESUMO

A rapid sandwich enzyme-linked immunosorbent assay (ELISA)-based in vitro diagnostic (IVD) procedure has been developed for human fetuin A (HFA), an important disease biomarker for inflammatory diseases as well as malignancies. In this simplified and cost-effective procedure, the EDC-activated anti-HFA antibody (Ab) was admixed with 1% (v/v) 3-aminopropyltriethoxysilane (APTES) in 1:1 (v/v) and dispensed in a KOH-pretreated microtiter plate (MTP). APTES formed a stable complex with the capture antibody that was in turn covalently bonded on the KOH-treated surface in 30 min. The resulting immunoassay (IA) format detects HFA with a dynamic range of 0.1-243 ng mL(-1), and a limit of detection (LOD) and analytical sensitivity of 0.3 ng mL(-1) and 1.0 ng mL(-1), respectively. For the determination of HFA spiked in diluted human whole blood and serum, and HFA in ethylenediaminetetraacetic acid (EDTA)-plasma of patients, the obtained analytical precision is similar to that of the conventional sandwich ELISA. The anti-HFA Ab-bound MTPs, stored at 4 °C in 0.1M PBS, pH 7.4, retained its biological activity for 8 weeks, thereby demonstrating excellent storage stability. This generic sandwich ELISA procedure can be extended for rapid, simplified and cost-effective detection of other disease biomarkers.


Assuntos
Técnicas Biossensoriais , Ensaio de Imunoadsorção Enzimática , alfa-2-Glicoproteína-HS/isolamento & purificação , Análise Química do Sangue , Humanos , Neoplasias/sangue , Neoplasias/diagnóstico , alfa-2-Glicoproteína-HS/química
16.
Biosens Bioelectron ; 66: 169-76, 2015 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-25460898

RESUMO

A novel immunoassay (IA) has been developed for human C-reactive protein (CRP), an important biomarker and tissue preserving factor for infection and inflammation. Graphene nanoplatelets (GNP) and 3-aminopropyltriethoxysilane (APTES) were admixed and covalently attached to a polystyrene based-microtiter plate (MTP), pretreated with KOH. The resulting surface served as a stable layer for the covalent attachment of the anti-human CRP antibody. The IA procedure was based on the one-step kinetics-based sandwich IA employing a minimum number of process steps, whereas the enzymatic reaction solution was monitored by a smartphone-based colorimetric reader. With a limit of detection and a limit of quantification of 0.07ngmL(-1) and 0.9ngmL(-1), it precisely detected CRP spiked in diluted human whole blood and plasma as well as the CRP levels in clinical plasma samples. The results obtained for "real-world" patient samples agreed well with those of the conventional immunosorbent assay and the clinically-accredited analyzer-based IA. The antibody-bound GNP-functionalized MTPs retained its original activity after 6 weeks of storage in 0.1M PBS, pH 7.4 at 4°C.


Assuntos
Técnicas Biossensoriais/métodos , Proteína C-Reativa/isolamento & purificação , Grafite/química , Imunoensaio/métodos , Anticorpos/química , Telefone Celular , Colorimetria , Humanos
18.
Anal Biochem ; 456: 32-7, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24732114

RESUMO

This article reveals a rapid sandwich enzyme-linked immunosorbent assay (ELISA) for the highly sensitive detection of human C-reactive protein (CRP) in less than 30 min. It employs a one-step kinetics-based highly simplified and cost-effective sandwich ELISA procedure with minimal process steps. The procedure involves the formation of a sandwich immune complex on capture anti-human CRP antibody-bound Dynabeads in 15 min, followed by two magnet-assisted washings and one enzymatic reaction. The developed sandwich ELISA detects CRP in the dynamic range of 0.3 to 81 ng ml(-1) with a limit of detection of 0.4 ng ml(-1) and an analytical sensitivity of 0.7 ng ml(-1). It detects CRP spiked in diluted human whole blood and serum with high analytical precision, as confirmed by conventional sandwich ELISA. Moreover, the results of the developed ELISA for the determination of CRP in the ethylenediaminetetraacetic acid plasma samples of patients are in good agreement with those obtained by the conventional ELISA. The developed immunoassay has immense potential for the development of rapid and cost-effective in vitro diagnostic kits.


Assuntos
Proteína C-Reativa/análise , Ensaio de Imunoadsorção Enzimática/métodos , Análise Custo-Benefício , Ensaio de Imunoadsorção Enzimática/economia , Humanos , Cinética
19.
Sci Rep ; 4: 4407, 2014 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-24638258

RESUMO

An improved enzyme-linked immunosorbent (ELISA) assay using one-step antibody immobilization has been developed for the detection of human fetuin A (HFA), a specific biomarker for atherosclerosis and hepatocellular carcinoma. The anti-HFA formed a stable complex with 3-aminopropyltriethoxysilane (APTES) by ionic and hydrophobic interactions. The complex adsorbed on microtiter plates exhibited a detection range of 4.9 pg mL(-1) to 20 ng mL(-1) HFA, with a limit of detection of 7 pg mL(-1). Furthermore, an analytical sensitivity of 10 pg mL(-1) was achieved, representing a 51-fold increase in sensitivity over the commercial sandwich ELISA kit. The results obtained for HFA spiked in diluted human whole blood and plasma showed the same precision as the commercial kit. When stored at 4°C in 0.1 M phosphate-buffered saline (PBS, pH 7.4), the anti-HFA bound microtiter plates displayed no significant decrease in their functional activity after two months. The new ELISA procedure was extended for the detection of C-reactive protein, human albumin and human lipocalin-2 with excellent analytical performance.


Assuntos
Anticorpos Imobilizados , Aterosclerose/diagnóstico , Carcinoma Hepatocelular/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , Neoplasias Hepáticas/diagnóstico , alfa-2-Glicoproteína-HS/análise , Proteínas de Fase Aguda , Anticorpos Imobilizados/química , Complexo Antígeno-Anticorpo/química , Aterosclerose/sangue , Biomarcadores/sangue , Proteína C-Reativa/análise , Carcinoma Hepatocelular/sangue , Humanos , Interações Hidrofóbicas e Hidrofílicas , Limite de Detecção , Lipocalina-2 , Lipocalinas/sangue , Neoplasias Hepáticas/sangue , Propilaminas , Proteínas Proto-Oncogênicas/sangue , Albumina Sérica/análise , Silanos/química
20.
Diagnostics (Basel) ; 4(3): 104-28, 2014 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-26852680

RESUMO

Smartphone-based devices and applications (SBDAs) with cost effectiveness and remote sensing are the most promising and effective means of delivering mobile healthcare (mHealthcare). Several SBDAs have been commercialized for the personalized monitoring and/or management of basic physiological parameters, such as blood pressure, weight, body analysis, pulse rate, electrocardiograph, blood glucose, blood glucose saturation, sleeping and physical activity. With advances in Bluetooth technology, software, cloud computing and remote sensing, SBDAs provide real-time on-site analysis and telemedicine opportunities in remote areas. This scenario is of utmost importance for developing countries, where the number of smartphone users is about 70% of 6.8 billion cell phone subscribers worldwide with limited access to basic healthcare service. The technology platform facilitates patient-doctor communication and the patients to effectively manage and keep track of their medical conditions. Besides tremendous healthcare cost savings, SBDAs are very critical for the monitoring and effective management of emerging epidemics and food contamination outbreaks. The next decade will witness pioneering advances and increasing applications of SBDAs in this exponentially growing field of mHealthcare. This article provides a critical review of commercial SBDAs that are being widely used for personalized healthcare monitoring and management.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...